EKOHEAT® 75, 100 & 125 kW | 15-40 kHz Systems

Max Power
75, 100 & 125 kW

Frequency
15-40 kHz

Line Voltage
360 - 520 3Ø Vac

EKOHEAT Compact Series 75 kW, 100 kW & 125 kW  Induction Heating Systems

Power to 125 kW
Operation from 15 kHz to 40 kHz
50% SMALLER : Same Power Rating!

EKOHEAT Compact Series 75 kW, 100 kW & 125 kW  Induction Heating Systems for the 15 to 40 kHz range provide reliable and repeatable solutions for heating larger parts that require higher frequencies. Among the many typical applications are heat treating of steels, preheating for forging of steel, aluminum, copper or brass, crystal growing, and heating of graphite and metal crucibles.

EKOHEAT 125/25c Group is Versatile

♦ Efficient heating of many part geometries, sizes and compositions
♦ Multiple capacitor configurations
♦ Multiple tap transformer configurations
♦ Voltage or Power control
♦ Repeatable, reliable heating, agile frequency tuning
♦ Through-Curie heating
♦ Movable workhead; up to 30m (100’)
♦ Sub-second to continuous cycle times
♦ Remote operation or logging with RS485 port
♦ Accepts international AC line voltages

EKOHEAT 125/25c Group is Easy to Use

♦ User-friendly operator front panel controls
♦ System configuration from front panel
♦ Cycle timer, peak and short-cycle data capture
♦ 10 ten-step heating profiles
♦ Overload-tolerant output management
♦ 5-language display suite (EN, ES, FR, DE, IT)
♦ System diagnostics displayed on front panel

EKOHEAT is CE marked and manufactured at our IS0 9001:2015 certified facility.

With our versatile Compact Series EKOHEAT power control system you get rapid tuning, efficient and precise heating of your parts, power control within 0.2% resolution and an easy-to-use, easy-to-read front panel. Remote control is accomplished with 0-10V, 4-20mA inputs, RS485 serial port, 24V controls, Modbus and remote E-Stop input so integration with your automated production lines is easy. All of this functionality is now available in an enclosure size that is 50% smaller than standard systems.

EKOHEAT technology improves return on investment by reducing your energy usage compared to gas-fired and resistive heating techniques. Flameless, non-contact induction heating minimizes energy waste by focusing energy only on the part and zone to be heated. With very efficient power conversion and a power factor greater than 0.9, utility demand charges are reduced, lowering monthly energy bills.

A separate cabinet houses the resonating capacitor bank, available in several different sizes to meet customer-specific applications. This workhead may be placed up to 30 meters from the power supply. Alternatively the resonating capacitor may be mounted in an extra bay to locate it with the power supply.

This is a water-cooled system, requiring connection to a heat exchanger or other means of dissipating heat. EKOHEAT systems are CE marked.

Select an option below:
  • 75 kW
  • 100 kW
  • 125 kW

SPECIFICATION

VALUE

UNITS

RF Terminal Power1

75

kW

AC Line Power

87

kVA

AC Line Protection2

225

A

Output Frequency

15 - 40

kHz

Power Factor

0.92

 

AC Line Voltage

360 - 520

Vac

Display

LCD Monochrome, 240w x 128h Pixels

 

Serial Communications

MODBUS RTU, RS485 standard (RS485/232 converter optional)

Optional

Process Timer

0.01 – 910,799

sec

Max Ambient Temp

45 (115)

C° (F°)

Compliance3

CE, UKCA, EN55011, EN60519-1, EN60519-3

 

Ingress Protection

IP54, NEMA 12

 

Dimensions

658 (25.9) x 551 (21.7) x 1561 (61.5)

WxDxH mm (in)

Weight

193 (425)

kg (lb)

WATER COOLING

Flow4

17.8 (4.7)

l/m (g/m)

Max Input Pressure

5.6 (80)

bar (lb/in2)

Pressure Differential

2.8 - 5.6 (40-80)

bar (lb/in2)

Max Water Temp

35 (95)

C° (F°)

1) Maximum output may vary by frequency and load conditions
2) Fast-acting fuses
3) Suitable for incorporation into equipment for compliance with Machinery Directive
4) Power supply; workhead coil flow requirements vary by application

SPECIFICATION

VALUE

UNITS

RF Terminal Power1

100

kW

AC Line Power

116

kVA

AC Line Protection2

225

A

Output Frequency

15 - 40

kHz

Power Factor

0.92

 

AC Line Voltage

360 - 520

Vac

Display

LCD Monochrome, 240w x 128h Pixels

 

Serial Communications

MODBUS RTU, RS485 standard (RS485/232 converter optional)

Optional

Process Timer

0.01 – 910,799

sec

Max Ambient Temp

45 (115)

C° (F°)

Compliance3

CE, UKCA, EN55011, EN60519-1, EN60519-3

 

Ingress Protection

IP54, NEMA 12

 

Dimensions

658 (25.9) x 551 (21.7) x 1561 (61.5)

WxDxH mm (in)

Weight

193 (425)

kg (lb)

WATER COOLING

Flow4

17.8 (4.7)

l/m (g/m)

Max Input Pressure

5.6 (80)

bar (lb/in2)

Pressure Differential

2.8 - 5.6 (40-80)

bar (lb/in2)

Max Water Temp

35 (95)

C° (F°)

1) Maximum output may vary by frequency and load conditions
2) Fast-acting fuses
3) Suitable for incorporation into equipment for compliance with Machinery Directive
4) Power supply; workhead coil flow requirements vary by application

SPECIFICATION

VALUE

UNITS

RF Terminal Power1

125

kW

AC Line Power

145

kVA

AC Line Protection2

300

A

Output Frequency

15 - 40

kHz

Power Factor

0.92

 

AC Line Voltage

360 - 520

Vac

Display

LCD Monochrome, 240w x 128h Pixels

 

Serial Communications

MODBUS RTU, RS485 standard (RS485/232 converter optional)

Optional

Process Timer

0.01 – 910,799

sec

Max Ambient Temp

45 (115)

C° (F°)

Compliance3

CE, UKCA, EN55011, EN60519-1, EN60519-3

 

Ingress Protection

IP54, NEMA 12

 

Dimensions

658 (25.9) x 551 (21.7) x 1561 (61.5)

WxDxH mm (in)

Weight

193 (425)

kg (lb)

WATER COOLING

Flow4

17.8 (4.7)

l/m (g/m)

Max Input Pressure

5.6 (80)

bar (lb/in2)

Pressure Differential

2.8 - 5.6 (40-80)

bar (lb/in2)

Max Water Temp

35 (95)

C° (F°)

1) Maximum output may vary by frequency and load conditions
2) Fast-acting fuses
3) Suitable for incorporation into equipment for compliance with Machinery Directive
4) Power supply; workhead coil flow requirements vary by application

Four Ways To Contact Ambrell for Support

AMBRELL CORPORATION

1655 Lyell Avenue
Rochester, NY 14606
United States
 

Directions to Ambrell Corporation Directions

T: +1 585 889 9000

F: +1 585 889 4030

Contact Sales

Contact Orders

Contact Service

S: +1 585 889 0200

AMBRELL B.V.

Holtersweg 1
7556 BS Hengelo
The Netherlands
 

Directions to Ambrell B. V. Directions

T: +31 880 150 100

F: +31 546 788 154

Contact Sales

Contact Orders

Contact Service

AMBRELL Ltd.

Unit 6, Space Business Centre
Tewkesbury Road
Cheltenham, GLOS, GL51 9FL
United Kingdom

Directions to Ambrell Ltd.Directions

T: +44 1242 514042

F: +31 546 788 154

Contact Sales

Contact Orders

Contact Service