Note: Heating a catheter tipping die
Objective:
Water-cooled brass mandrel die, nylon LDPE catheter, “K” type thermocouple and temperature controller.
End Product:
Catheter
Equipment:
Ambrell 3kW induction heating system, remote heat station containing one 0.66 μF capacitor.
Materials:
N/A
Temperature:
400 °F (204°C)
Frequency:
325 kHz
Testing:
A two-turn plate concentrator coil is used to heat the die. To measure the temperature on the ID and establish the time-to-temperature relationship, the thermocouple is inserted inside the brass die. RF power is applied for 3 seconds to heat the die to 400 °F (204 °C). The nylon tube is pushed into the die and formed into a catheter.
Benefits:
-
Increased throughput and reduced cycle time
-
Consistent and repeatable results
-
Clean heating
-
Precise temperature control

Visit our Applications Lab to learn more about free applications testing.